[转帖]Megacli 错误码

megacli,错误码 · 浏览次数 : 0

小编点评

| Error Code | Command | Description | |---|---|---| | 0x00 | Command completed successfully | 命令完成成功 | | 0x01 | Invalid command | 命令无效 | | 0x02 | DCMD opcode is invalid | DCMD指令无效 | | 0x03 | Input parameters are invalid | 输入参数无效 | | 0x04 | Invalid sequence number | 序列号无效 | | 0x05 | Abort isn't possible for the requested command | 无法进行此命令的请求 | | 0x06 | Application 'host' code not found | 应用 'host' 代码未找到 | | 0x07 | Application already in use - try later | 应用已在使用中,请稍后尝试 | | 0x08 | Application not initialized | 应用未初始化 | | 0x09 | Given array index is invalid | 索引的数组元素无效 | | 0x0a | Unable to add missing drive to array, as row has no empty slots | 无法添加缺少驱动到数组,因为该行没有空缺的槽 | | 0x0b | Some of the CFG resources conflict with each other or the current config | CFG 资源冲突或与当前配置冲突 | | 0x0c | Invalid device ID / select-timeout | 设备 ID或选择超时无效 | | 0x0d | Drive is too small for requested operation |驱动尺寸不足以执行该操作 | | 0x0e | Flash memory allocation failed | 存储器分配失败 | | 0x0f | Flash download already in progress | 存储器下载正在进行 | | 0x10 | Flash operation failed | 存储器操作失败 | | 0x11 | Flash image was bad | 存储器图像无效 | | 0x12 | Downloaded flash image is incomplete | 下载的存储器图像缺失 | | 0x13 | Flash OPEN was not done | 存储器打开未完成 | | 0x14 | Flash sequence is not active | 存储器序列不活跃 | | 0x15 | Flush command failed | 刷新命令失败 | | 0x16 | Specified application doesn't have host-resident code | 指定的应用缺乏主机寄存代码 | | 0x17 | LD operation not possible - CC is in progress | LD操作不可进行 - CC正在进行 | | 0x18 | LD initialization in progress | LD初始化在进行 | | 0x19 | LBA is out of range | LBA超出范围 | | 0x1a | Maximum LDs are already configured | 最大 LD已配置完成 | | 0x1b | LD is not OPTIMAL | LD不是最佳性能 | | 0x1c | LD Rebuild is in progress | LD重建在进行 | | 0x1d | LD is undergoing reconstruction | LD正在进行重建 | | 0x1e | LD RAID level is wrong for requested operation | 存储器组级别不匹配该操作 | | 0x1f | Too many spares assigned | 预设分配的额外空间过多 | | 0x20 | Scratch memory not available - try command again later | 闪存内存不可用 - 请稍后尝试再次 | | 0x21 | Error writing MFC data to SEEPROM | 写入 MFC 数据到 SEEPROM 时发生错误 | | 0x22 | Required HW is missing (i.e. Alarm or BBU) | 要求的硬件缺失 (例如警报或 BBU) | | 0x23 | Item not found | 未找到 item | | 0x24 | LD drives are not within an enclosure | LD驱动不在房间内 | | 0x25 | PD CLEAR operation is in progress | PD 清理操作在进行 | | 0x26 | Unable to use SATA(SAS) drive to replace SAS(SATA) | 使用 SATA(SAS)驱动替换 SAS(SATA)不可用 | | 0x27 | Patrol Read is disabled | Patrol读取被禁用 | | 0x28 | Given row index is invalid | 行索引无效 | | 0x2d | SCSI command done, but non-GOOD status was received - see mf.hdr.extStatus | 执行 SCSI 命令,但获得非良好状态 - 查看 mf.hdr.extStatus | | 0x2f | Matches SCSI RESERVATION_CONFLICT | 与 SCSI RESERVATION_CONFLICT 冲突 | | 0x30 | One or more of the flush operations failed | 存在多个刷新操作失败 | | 0x31 | FW real-time currently not set | FW实时当前未设置 | | 0x32 | Command issues while FW in wrong state (i.e. GET RECON when op not active) | 命令在FW状态错误 (即当 op 非活动时获取重建命令时出现错误) | | 0x33 | LD is not OFFLINE - IO not possible | LD不是在线 - IO不可进行 | | 0x34 | Peer controller rejected request (possibly due to resource conflict) | ピア控制器拒绝请求 (可能由于资源冲突) | | 0x35 | Unable to inform peer of communication changes (retry might be appropriate) | 无法通知ピア的通信变更 (尝试再次尝试) | | 0x36 | Invalid device ID or select-timeout | 设备 ID或选择超时无效 |

正文

  1. MegaCLI Error Messages
  2. 0x00 Command completed successfully
  3. 0x01 Invalid command
  4. 0x02 DCMD opcode is invalid
  5. 0x03 Input parameters are invalid
  6. 0x04 Invalid sequence number
  7. 0x05 Abort isn't possible for the requested command
  8. 0x06 Application 'host' code not found
  9. 0x07 Application already in use - try later
  10. 0x08 Application not initialized
  11. 0x09 Given array index is invalid
  12. 0x0a Unable to add missing drive to array, as row has no empty slots
  13. 0x0b Some of the CFG resources conflict with each other or the current config
  14. 0x0c Invalid device ID / select-timeout
  15. 0x0d Drive is too small for requested operation
  16. 0x0e Flash memory allocation failed
  17. 0x0f Flash download already in progress
  18. 0x10 Flash operation failed
  19. 0x11 Flash image was bad
  20. 0x12 Downloaded flash image is incomplete
  21. 0x13 Flash OPEN was not done
  22. 0x14 Flash sequence is not active
  23. 0x15 Flush command failed
  24. 0x16 Specified application doesn't have host-resident code
  25. 0x17 LD operation not possibe - CC is in progress
  26. 0x18 LD initialization in progress
  27. 0x19 LBA is out of range
  28. 0x1a Maximum LDs are already configured
  29. 0x1b LD is not OPTIMAL
  30. 0x1c LD Rebuild is in progress
  31. 0x1d LD is undergoing reconstruction
  32. 0x1e LD RAID level is wrong for requested operation
  33. 0x1f Too many spares assigned
  34. 0x20 Scratch memory not available - try command again later
  35. 0x21 Error writing MFC data to SEEPROM
  36. 0x22 Required HW is missing (i.e. Alarm or BBU)
  37. 0x23 Item not found
  38. 0x24 LD drives are not within an enclosure
  39. 0x25 PD CLEAR operation is in progress
  40. 0x26 Unable to use SATA(SAS) drive to replace SAS(SATA)
  41. 0x27 Patrol Read is disabled
  42. 0x28 Given row index is invalid
  43. 0x2d SCSI command done, but non-GOOD status was received - see mf.hdr.extStatus for SCSI_STATUS
  44. 0x2e IO request for MFI_CMD_OP_PD_SCSI failed - see extStatus for DM error
  45. 0x2f Matches SCSI RESERVATION_CONFLICT
  46. 0x30 One or more of the flush operations failed
  47. 0x31 FW real-time currently not set
  48. 0x32 Command issues while FW in wrong state (i.e. GET RECON when op not active)
  49. 0x33 LD is not OFFLINE - IO not possible
  50. 0x34 Peer controller rejected request (possibly due to resource conflict)
  51. 0x35 Unable to inform peer of communication changes (retry might be appropriate)
  52. 0x36 LD reservation already in progress
  53. 0x37 I2C errors were detected
  54. 0x38 PCI errors occurred during XOR/DMA operation
  55. 0x39 Diagnostics failed - see event log for details
  56. 0x3a Unable to process command as boot messages are pending
  57. 0x3b Returned in case if foreign configurations are imcomplete
  58. 0x3d Returned in case if a command is tried on unsupported hardware
  59. 0x3e CC scheduling is disabled
  60. 0x3f PD CopyBack operation is in progress
  61. 0x40 Selected more than one PD per array
  62. 0x41 Microcode update operation failed
  63. 0x42 Unable to process command as drive security feature is not enabled
  64. 0x43 Controller already has a lock key
  65. 0x44 Lock key cannot be backed-up
  66. 0x45 Lock key backup cannot be verified
  67. 0x46 Lock key from backup failed verification
  68. 0x47 Rekey operation not allowed, unless controller already has a lock key
  69. 0x48 Lock key is not valid, cannot authenticate
  70. 0x49 Lock key from escrow cannot be used
  71. 0x4a Lock key backup (pass-phrase) is required
  72. 0x4b Secure LD exist
  73. 0x4c LD secure operation is not allowed
  74. 0x4d Reprovisioning is not allowed

与[转帖]Megacli 错误码相似的内容:

[转帖]Megacli 错误码

MegaCLI Error Messages 0x00 Command completed successfully 0x01 Invalid command 0x02 DCMD opcode is invalid 0x03 Input parameters are invalid 0x04 Inv

[转帖]【MegaCli】RAID工具管理工具学习与整理

https://blog.yelvlab.cn/archives/608/ 95年小孩写的文章. MegaCli MegaCli是一款管理维护硬件RAID软件,可以通过它来了解当前raid卡的所有信息,包括 raid卡的型号,raid的阵列类型,raid 上各磁盘状态,等等。通常,我们对硬盘当前的状

[转帖]Megacli常用命令汇总

MegaCli 是一款管理维护硬件 RAID 软件,可以通过它来了解当前 raid 卡的所有信息,包括 raid 卡的型号,raid 的阵列类型,raid 上各磁盘状态,等 。通常,我们对硬盘当前的状态不太 好确定,一般通过机房人员巡检来完成,有没有通过软件的方式来检查确定这个问题呢。 MegaCl

[转帖]MegaCli命令

MegaCli命令 设置jbod模式 1.3 LSI 9260/9261 raid卡配置 LSI 9260/9261 raid卡支持0、1、10、5、6、50、60 常用命令: 清除raid卡原有的配置信息 MegaCli -cfgclr -a0 查看RAID卡设备ID MegaCli -pdlis

【转帖】ESXI上安装和使用MegaCli

https://www.diewufeiyang.com/post/964.html 一、第一步获取安装文件,官网目前搜索也找不到了,这里附件提供之前保存的安装文件 点击下载 二、使用VMware vSphere Client连接ESXI在配置里启用ssh服务,然后通过ssh客户端工具连接ESXI,

[转帖]arcconf工具简单学习

https://blog.yelvlab.cn/archives/622/ 最近用到了一个MICROCHIP公司的阵列卡Microsemi Adaptec SmartRAID 3152-8i,但是常用的Raid Manager工具megacli,并不兼容这张卡,无法进行管理和监控,所以研究一下能管理

[转帖]

Linux ubuntu20.04 网络配置(图文教程) 因为我是刚装好的最小系统,所以很多东西都没有,在开始配置之前需要做下准备 环境准备 系统:ubuntu20.04网卡:双网卡 网卡一:供连接互联网使用网卡二:供连接内网使用(看情况,如果一张网卡足够,没必要做第二张网卡) 工具: net-to

[转帖]

https://cloud.tencent.com/developer/article/2168105?areaSource=104001.13&traceId=zcVNsKTUApF9rNJSkcCbB 前言 Redis作为高性能的内存数据库,在大数据量的情况下也会遇到性能瓶颈,日常开发中只有时刻

[转帖]ISV 、OSV、 SIG 概念

ISV 、OSV、 SIG 概念 2022-10-14 12:29530原创大杂烩 本文链接:https://www.cndba.cn/dave/article/108699 1. ISV: Independent Software Vendors “独立软件开发商”,特指专门从事软件的开发、生产、

[转帖]Redis 7 参数 修改 说明

2022-06-16 14:491800原创Redis 本文链接:https://www.cndba.cn/dave/article/108066 在之前的博客我们介绍了Redis 7 的安装和配置,如下: Linux 7.8 平台 Redis 7 安装并配置开机自启动 操作手册https://ww